[. . . ] [. . . ] The safety device of the burner shuts off the gas supply to the burner if its flame goes out accidentally (because of a sudden gust of wind, an interruption in the gas delivery, the overflowing of liquids, etc. ). -- At the same time, keep the knob pressed against the control panel until the burners ignites. · After the burner has ignited, keep the knob pressed for about 10 seconds. If the burner does not ignite, repeat the operations described above. · 5019 319 01424 DIMENSIONS OF COOKING HOB AND WORKTOP (mm) NOTE: In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance. INJECTORS TABLE CATEGORY II2H3+ Type of gas used Type of burner large medium small large medium small large medium small Injector marking Y 115 H2 98 X 72 87 65 50 87 65 50 Rated heat capacity kW 3. 00 1. 65 1. 00 3. 00 1. 65 1. 00 3. 00 1. 65 1. 00 Rated consumption 286 l/h 157 l/h 95 l/h 218 l/h 120 l/h 73 l/h 214 l/h 118 l/h 71 l/h Reduced heat capacity kW 0. 60 0. 35 0. 30 0. 60 0. 35 0. 30 0. 60 0. 35 0. 30 Gas pressure mbar min. [. . . ] [. . . ]